GNSS Measurement Gap Procedure in LTE-M NTN: Complete 3GPP Explanation, HARQ Timing and UE Operation
Introduction to GNSS Measurement Gap in LTE-M NTN
Non-Terrestrial Networks (NTN) are transforming wireless communication by extending cellular connectivity through satellites and other airborne platforms. Unlike conventional terrestrial networks, NTN introduces additional challenges related to satellite movement, long propagation delays, Doppler frequency shifts and geographical positioning.GNSS Measurement Gap Procedure in LTE-M NTN
In LTE-M NTN, Global Navigation Satellite System (GNSS) measurements play a critical role in helping the User Equipment (UE) determine its geographical position.
The UE uses valid GNSS information to support satellite communication operations, including timing and frequency pre-compensation required for reliable communication with the satellite-based network.GNSS Measurement Gap Procedure in LTE-M NTN
However, the UE cannot always perform GNSS measurements while continuously receiving network control information and maintaining normal communication activities.
To address this challenge, 3GPP introduces the GNSS Measurement Gap Procedure in LTE-M NTN.
This procedure allows the LTE-M NTN eNB to trigger GNSS measurements through a GNSS Measurement Command MAC Control Element (MAC CE), providing the UE with a dedicated time interval to reacquire its GNSS position.
An important part of this procedure is the coordination between HARQ feedback timing, downlink scheduling and the beginning of the GNSS measurement gap.
This article explains the complete procedure, including the n+6 and k+2 timing rules, PDSCH reception, PUSCH HARQ-ACK transmission, MPDCCH monitoring restrictions and contention-based Random Access.

Table of Contents
Introduction to GNSS Measurement Gap in LTE-M NTN
Why GNSS Measurements Are Important in LTE-M NTN
What Is a GNSS Measurement Gap?
Role of GNSS Measurement Command MAC CE
GNSS Measurement Gap Procedure in LTE-M NTN
HARQ-ACK Disabled Scenario: Measurement Gap Starts at n+6
HARQ-ACK Enabled Scenario: Measurement Gap Starts at k+2
Role of PDSCH and PUSCH in GNSS Measurement
MPDCCH Monitoring During GNSS Measurement Gap
GNSS Reacquisition and Contention-Based Random Access
Complete GNSS Measurement Gap Signaling Flow
HARQ-ACK Enabled vs Disabled: Key Differences
Technical Challenges in LTE-M NTN GNSS Measurement
Practical Example of GNSS Measurement Gap
Importance of GNSS Measurement Gap in Satellite Communication
Protocol Testing and Log Analysis Perspective
Career Opportunities in LTE-M NTN and Satellite Communication
Why Apeksha Telecom – The Telecom Gurukul?
Frequently Asked Questions (FAQs)
Conclusion
Why GNSS Measurements Are Important in LTE-M NTN
In terrestrial LTE networks, the UE generally communicates with a relatively stationary base station. The propagation delay and timing relationships are comparatively predictable.
In satellite-based NTN communication, the situation is different.
A satellite may be moving at high speed relative to the UE, and the distance between the satellite and the UE can be significantly greater than the distance between a UE and a terrestrial eNodeB.
These conditions introduce several challenges:
Satellite Position Awareness
The UE needs accurate geographical positioning information to support NTN communication procedures.
Timing Advance Calculation
The network needs to account for the propagation delay between the UE and the satellite to maintain uplink synchronization.
Doppler Compensation
Satellite movement introduces Doppler frequency shifts. GNSS-based positioning and associated satellite information help support frequency pre-compensation.
Uplink Synchronization
Valid GNSS information helps the UE maintain the timing and frequency conditions required for reliable uplink transmission.
Continuous NTN Connectivity
GNSS information may become outdated after a certain validity period. Therefore, the UE needs to perform GNSS measurements again to obtain an updated position.
Without valid GNSS measurements, the LTE-M NTN UE cannot utilize the NTN connection for normal data transfer as described in the relevant procedure.
This makes GNSS measurement and reacquisition an essential part of LTE-M NTN operation.
What Is a GNSS Measurement Gap?
A GNSS Measurement Gap is a dedicated time interval during which the LTE-M NTN UE performs GNSS measurements without being required to monitor normal network control information.
During this interval, the UE focuses on acquiring or reacquiring its geographical position using GNSS signals.
GNSS measurement gaps are particularly important in NTN because satellite communication depends on accurate positioning and timing-related information.
The LTE-M NTN eNB can initiate this process by transmitting a GNSS Measurement Command MAC CE through the Physical Downlink Shared Channel (PDSCH).
Once the UE receives the command, it determines when the measurement gap should begin.
The starting time depends on whether HARQ-ACK feedback is required for the downlink transport block carrying the command.
There are two important scenarios:
HARQ-ACK Disabled: The measurement gap starts at subframe n+6.
HARQ-ACK Enabled: The measurement gap starts at subframe k+2.
These timing rules ensure that the GNSS measurement process does not interfere with the required HARQ feedback transmission.
Role of GNSS Measurement Command MAC CE
The GNSS Measurement Command MAC Control Element is used by the LTE-M NTN eNB to trigger GNSS measurement activity at the UE.
The command is transmitted inside a MAC PDU carried by the PDSCH.
When the UE receives this MAC CE, it processes the instruction and determines the appropriate starting point for the GNSS measurement gap.
The GNSS Measurement Command MAC CE is important because it provides network-controlled coordination for GNSS measurement operations.
According to 3GPP TS 36.321, the GNSS Measurement Command MAC CE contains information related to the measurement trigger and GNSS measurement gap length.
Its fields include:
T (Type): Indicates whether the UE should perform GNSS measurements immediately using the configured gap or store the gap length for subsequent UE-autonomous GNSS measurement.
R (Reserved): Reserved bit, set to 0.
GNSS Measurement Gap Length: Specifies the configured duration of the GNSS measurement gap.
The gap length field is 4 bits long.
The specified gap-length values include:
Codepoint | Gap Length |
0000 | 1 second |
0001 | 2 seconds |
0010 | 3 seconds |
0011 | 4 seconds |
0100 | 5 seconds |
0101 | 6 seconds |
0110 | 7 seconds |
0111 | 13 seconds |
1000 | 19 seconds |
1001 | 25 seconds |
1010 | 31 seconds |
1011–1111 | Reserved |
This configuration allows the UE to use the required measurement duration for GNSS acquisition or reacquisition.
The GNSS Measurement Command MAC CE therefore plays a central role in coordinating network-triggered GNSS measurements.
GNSS Measurement Gap Procedure in LTE-M NTN
The GNSS Measurement Gap Procedure starts when the LTE-M NTN UE receives a GNSS Measurement Command MAC CE from the eNB.
The command is transmitted through the PDSCH.
For understanding the procedure, assume that the UE receives the GNSS Measurement Command MAC CE in downlink subframe n.
The UE then determines the beginning of the measurement gap based on the HARQ feedback configuration associated with the transport block.
The procedure follows these steps:
Step 1: GNSS Measurement Command Transmission
The LTE-M NTN eNB transmits the GNSS Measurement Command MAC CE through the PDSCH.
Step 2: UE Receives the Command
The LTE-M NTN UE receives the transport block containing the MAC CE in subframe n.
Step 3: HARQ Feedback Evaluation
The UE determines whether HARQ-ACK information is required for the HARQ process associated with the received transport block.
Step 4: Measurement Gap Starting Time Calculation
Depending on the HARQ feedback requirement, the UE calculates the starting subframe:
Without HARQ-ACK: n+6.
With HARQ-ACK: k+2.
Step 5: GNSS Measurement Begins
The UE starts its GNSS measurement process when the calculated measurement gap begins.
Step 6: GNSS Position Reacquisition
The UE performs GNSS measurements to obtain a valid GNSS position.
Step 7: Contention-Based Random Access
After reacquiring its GNSS position, the UE performs contention-based Random Access to resume the required network interaction.
This procedure allows the UE to obtain updated GNSS information while maintaining the required coordination with the LTE-M NTN network.
HARQ-ACK Disabled Scenario: Measurement Gap Starts at n+6
The first scenario occurs when the UE is not required to provide HARQ-ACK information for the HARQ process associated with the transport block carrying the GNSS Measurement Command MAC CE.
In this situation, the UE does not need to wait for an uplink HARQ-ACK transmission.
Therefore, the measurement gap starts at subframe n+6.
Here:
n = Downlink subframe in which the GNSS Measurement Command MAC CE is received.
n+6 = Starting subframe of the GNSS measurement gap.
Example:
Assume that the LTE-M NTN UE receives the GNSS Measurement Command MAC CE in subframe 100.
Since HARQ-ACK information is not required, the UE calculates the measurement gap starting time as follows:
Measurement Gap Start = n+6
Measurement Gap Start = 100+6
Measurement Gap Start = 106
Therefore, the UE considers subframe 106 as the beginning of the GNSS measurement gap.
During this period, the UE can perform GNSS measurements without the need to transmit HARQ-ACK information for the associated downlink transport block.
This approach reduces the dependency on HARQ feedback timing and allows the UE to start GNSS measurements according to the specified timing rule.
HARQ-ACK Enabled Scenario: Measurement Gap Starts at k+2
The second scenario occurs when the UE is required to provide HARQ-ACK information for the transport block carrying the GNSS Measurement Command MAC CE.
In this case, the UE must first complete the associated HARQ feedback transmission before starting the GNSS measurement gap.
The HARQ-ACK response is transmitted through the Physical Uplink Shared Channel (PUSCH), according to the specified procedure.
The UE then identifies the first downlink subframe after the end of the PUSCH transmission carrying the ACK/NACK response.
This downlink subframe is represented by k.
The GNSS measurement gap starts at:
Measurement Gap Start = k+2
Where:
k = First downlink subframe after the end of the PUSCH transmission carrying the associated HARQ-ACK response.
k+2 = Starting subframe of the GNSS measurement gap.
Example:
Assume the following:
GNSS Measurement Command MAC CE is received in subframe 100.
HARQ-ACK information is required.
The UE transmits the associated ACK/NACK response through PUSCH.
The first downlink subframe after the PUSCH transmission ends is subframe 110.
Therefore:
Measurement Gap Start = k+2
Measurement Gap Start = 110+2
Measurement Gap Start = 112
The UE considers subframe 112 as the beginning of the GNSS measurement gap.
The important point is that the measurement gap does not start directly at n+6 in this scenario.
Instead, the UE waits until the associated HARQ feedback transmission has ended and then applies the k+2 timing rule.
This ensures that the GNSS measurement activity does not interrupt the required HARQ feedback procedure.
Role of PDSCH and PUSCH in GNSS Measurement
PDSCH and PUSCH are important physical channels involved in the GNSS Measurement Gap Procedure.
Both channels support different parts of the signaling process.
PDSCH (Physical Downlink Shared Channel)
The PDSCH is used by the LTE-M NTN eNB to transmit the downlink transport block containing the GNSS Measurement Command MAC CE.
The UE receives this transport block and identifies the GNSS measurement instruction.
PUSCH (Physical Uplink Shared Channel)
When HARQ-ACK feedback is required, the UE transmits the corresponding ACK/NACK response through PUSCH in the scenario described by the procedure.
The end of this PUSCH transmission determines the reference point used to calculate k.
The following table summarizes their roles:
Parameter | PDSCH | PUSCH |
Direction | Downlink | Uplink |
Transmitting Entity | eNB | UE |
Receiving Entity | UE | eNB |
Main Role | Carries GNSS Measurement Command MAC CE | Carries HARQ-ACK response |
Importance | Triggers GNSS measurement | Determines timing reference k |
The relationship between these channels is essential for correct GNSS measurement gap timing.
MPDCCH Monitoring During GNSS Measurement Gap
The Physical Downlink Control Channel (MPDCCH) is used in LTE-Machine Type Communication (LTE-MTC) to provide downlink control information to the UE.
Under normal operating conditions, the UE monitors the configured control channel to receive scheduling information and other control instructions.
However, GNSS measurement requires a dedicated time interval during which the UE can concentrate on acquiring GNSS signals.
To support this requirement, 3GPP defines a special monitoring behavior for the LTE-M NTN UE.
During the GNSS measurement gap, the UE is not required to monitor MPDCCH.
This restriction continues until the UE:
Reacquires a valid GNSS position.
Performs a contention-based Random Access procedure.
This behavior allows the UE to prioritize GNSS acquisition instead of continuously monitoring downlink control information.
It also prevents unnecessary control-channel monitoring during the dedicated GNSS measurement period.
GNSS Reacquisition and Contention-Based Random Access
After the GNSS measurement gap begins, the UE performs GNSS measurements to reacquire its geographical position.
GNSS reacquisition is important because the previously available position information may no longer be valid for NTN communication requirements.
Once the UE successfully obtains a valid GNSS position, it needs to perform the required network access procedure.
This involves contention-based Random Access.
The main objectives are:
Re-establishing the required uplink access.
Supporting uplink synchronization.
Allowing the UE to resume network communication.
Enabling subsequent NTN data transfer when the required conditions are satisfied.
The sequence can be understood as follows:
GNSS Measurement Command → GNSS Measurement Gap → GNSS Position Reacquisition → Contention-Based Random Access → Resumption of Network Operation
The UE is therefore not required to monitor MPDCCH throughout the specified measurement gap until GNSS position reacquisition and contention-based Random Access have been completed.
Complete GNSS Measurement Gap Signaling Flow
The complete procedure can be understood through the following signaling sequence.
Network Side (LTE-M NTN eNB)
The eNB determines that the UE needs GNSS measurement.
The eNB prepares the GNSS Measurement Command MAC CE.
The command is transmitted through the PDSCH.
UE Side (LTE-M NTN UE)
The UE receives the command in subframe n.
The UE checks whether HARQ-ACK information is required for the associated transport block.
Scenario A: HARQ-ACK Not Required
The UE calculates the measurement gap start as n+6.
The UE begins GNSS measurements.
Scenario B: HARQ-ACK Required
The UE transmits the associated ACK/NACK response through PUSCH.
The UE identifies k, the first downlink subframe after the end of the PUSCH transmission.
The UE calculates the measurement gap start as k+2.
The UE begins GNSS measurements.
Common Steps
The UE is not required to monitor MPDCCH during the GNSS measurement gap.
The UE reacquires its GNSS position.
The UE performs contention-based Random Access.
The UE can resume the required NTN network operations.
This signaling sequence ensures proper coordination between GNSS measurement, HARQ feedback and network access.
HARQ-ACK Enabled vs Disabled: Key Differences
One of the most important aspects of the LTE-M NTN GNSS Measurement Gap Procedure is the difference between HARQ-ACK enabled and disabled scenarios.
Parameter | HARQ-ACK Disabled | HARQ-ACK Enabled |
GNSS Command Reception | PDSCH | PDSCH |
HARQ Feedback | Not required | Required |
ACK/NACK Transmission | Not applicable | PUSCH |
Timing Reference | n | k |
Measurement Gap Start | n+6 | k+2 |
Waiting for HARQ Feedback | No | Yes |
GNSS Measurement | After gap begins | After gap begins |
Key Observation:
When HARQ-ACK feedback is disabled, the UE can calculate the measurement gap directly from the command reception subframe.
When HARQ-ACK feedback is enabled, the UE must consider the completion of the associated PUSCH transmission before calculating the measurement gap starting time.
This difference is critical for correct implementation and protocol testing.
Technical Challenges in LTE-M NTN GNSS Measurement
Although the GNSS Measurement Gap Procedure provides a structured approach, several technical challenges can arise during implementation and testing.
GNSS Signal Acquisition
GNSS signal acquisition can be affected by signal strength, satellite visibility, receiver sensitivity and environmental conditions.
HARQ Timing Coordination
Incorrect interpretation of HARQ feedback timing can result in an incorrect measurement gap starting point.
Satellite Propagation Delay
NTN introduces significant propagation delays that must be considered in communication timing.
MPDCCH Monitoring Restrictions
The UE must correctly handle the MPDCCH monitoring behavior during the GNSS measurement gap.
GNSS Position Validity
The UE needs to ensure that the reacquired GNSS position is valid before proceeding with subsequent NTN operations.
Random Access Synchronization
After GNSS reacquisition, the contention-based Random Access procedure must be completed successfully to support the resumption of network interaction.
These challenges make detailed protocol-level validation important for LTE-M NTN deployments.
Practical Example of GNSS Measurement Gap
Consider an LTE-M NTN network where the UE is connected to a satellite-based serving cell.
The eNB identifies that the UE needs updated GNSS measurements.
It sends a GNSS Measurement Command MAC CE through the PDSCH.
Assume the command is received in subframe 200.
Two possible scenarios can occur.
Scenario 1: HARQ-ACK Disabled
The UE is not required to send HARQ-ACK information.
Therefore:
n = 200
Measurement Gap Start = n+6
Measurement Gap Start = 206
The UE starts GNSS measurements from subframe 206.
Scenario 2: HARQ-ACK Enabled
The UE must transmit the ACK/NACK response through PUSCH.
Assume the first downlink subframe after the end of the associated PUSCH transmission is subframe 212.
Therefore:
k = 212
Measurement Gap Start = k+2
Measurement Gap Start = 214
The UE starts GNSS measurements from subframe 214.
Result:
The starting time of the GNSS measurement gap depends on the HARQ feedback requirement and the associated transmission timing.
This example demonstrates why understanding both timing rules is essential for LTE-M NTN protocol implementation and testing.
Importance of GNSS Measurement Gap in Satellite Communication
GNSS measurement gaps are an important part of reliable satellite-based cellular communication.
They support several important functions:
Maintaining updated geographical positioning information.
Supporting NTN timing and frequency pre-compensation.
Allowing GNSS reacquisition during connected operation.
Coordinating GNSS measurements with HARQ procedures.
Supporting reliable uplink synchronization.
Improving the operational coordination between UE and the satellite-based network.
As satellite-based IoT connectivity continues to develop, GNSS measurement procedures will remain an important area of LTE-M NTN and IoT NTN engineering.
Protocol Testing and Log Analysis Perspective
Understanding the GNSS Measurement Gap Procedure is important for engineers working in LTE-M NTN protocol testing, conformance testing and log analysis.
During protocol testing, engineers need to verify whether the UE and eNB follow the expected 3GPP signaling behavior.
Some important validation points include:
MAC CE Reception
Verify whether the UE correctly receives and decodes the GNSS Measurement Command MAC CE in the PDSCH transport block.
HARQ Configuration
Check whether HARQ-ACK feedback is required for the associated HARQ process.
Measurement Gap Timing
Verify the correct starting subframe:
n+6 when HARQ-ACK is not required.
k+2 when HARQ-ACK is required.
PUSCH HARQ-ACK Transmission
In the HARQ-enabled scenario, validate the associated ACK/NACK transmission and identify the correct reference subframe k.
MPDCCH Monitoring
Verify that the UE follows the specified MPDCCH monitoring restriction during the GNSS measurement gap.
GNSS Reacquisition
Check whether the UE successfully reacquires its GNSS position.
Random Access Procedure
Verify whether contention-based Random Access is performed after GNSS position reacquisition.
Engineers can use protocol log analyzers, chipset diagnostic tools and network simulation environments to investigate these procedures.
Commonly used tools in telecom protocol testing include:
Qualcomm QXDM
Qualcomm QCAT
Wireshark
Protocol Testers and Network Simulators
Python-based Log Analysis Tools
A detailed understanding of MAC, PHY, HARQ and Random Access procedures helps engineers identify signaling errors and troubleshoot NTN connectivity issues.
Career Opportunities in LTE-M NTN and Satellite Communication
The growth of Non-Terrestrial Networks is creating new opportunities for telecom engineers.
As mobile operators, satellite communication companies and network equipment manufacturers continue investing in NTN technologies, the demand for professionals with advanced protocol knowledge is increasing.
Some relevant job roles include:
LTE-M NTN Protocol Testing Engineer
Responsible for validating LTE-M NTN signaling procedures, protocol behavior and 3GPP compliance.
5G NTN Protocol Engineer
Works on NR-NTN and satellite-based 5G communication technologies.
3GPP Protocol Testing Engineer
Analyzes protocol specifications, call flows and signaling procedures.
RAN Development Engineer
Works on radio access network development, integration and optimization.
Telecom Log Analysis Engineer
Uses diagnostic tools to analyze protocol logs and troubleshoot network issues.
Satellite Communication Engineer
Works on satellite-based communication systems, synchronization and network integration.
To build a career in these domains, engineers should develop strong knowledge of:
LTE and LTE-M architecture.
5G NR and NR-NTN.
MAC, RLC, PDCP and RRC protocols.
NAS signaling.
HARQ procedures.
Random Access procedures.
3GPP specifications.
Protocol testing and log analysis.
A strong understanding of LTE and 5G protocol fundamentals provides an excellent foundation for advanced NTN technologies.
Why Apeksha Telecom – The Telecom Gurukul?
Apeksha Telecom – The Telecom Gurukul focuses on industry-oriented telecom training, including 4G/5G Protocol Testing, Log Analysis, 5G Technology, O-RAN, Telco Cloud and advanced telecom technologies.
The training approach emphasizes practical understanding of 3GPP specifications, protocol signaling, call flows and troubleshooting.
Key Learning Areas:
4G LTE Protocol Testing and Log Analysis.
5G NR Protocol Testing.
5G NTN and Satellite Communication Fundamentals.
NAS and RRC Signaling.
MAC, RLC and PDCP Protocols.
HARQ and Random Access Procedures.
QXDM and QCAT Log Analysis.
Wireshark and Protocol Analysis.
5G O-RAN and Telco Cloud.
With industry-focused training and practical protocol knowledge, learners can develop the technical foundation required for telecom engineering and testing roles.
Learn More:
Website: https://www.telecomgurukul.com/
Certification Courses: https://www.telecomgurukul.com/certification-course
Course Syllabus: https://www.telecomgurukul.com/syllabus
Frequently Asked Questions (FAQs)
Q1. What is the GNSS Measurement Gap Procedure in LTE-M NTN?
The GNSS Measurement Gap Procedure allows an LTE-M NTN UE to perform GNSS measurements by using a dedicated measurement interval triggered through the GNSS Measurement Command MAC CE.
Q2. Why does LTE-M NTN require GNSS measurements?
GNSS measurements provide geographical positioning information that supports NTN communication operations, including timing and frequency pre-compensation.
Q3. What is GNSS Measurement Command MAC CE?
It is a MAC Control Element transmitted by the LTE-M NTN eNB through the PDSCH to trigger GNSS measurement or configure a gap length for subsequent UE-autonomous measurements.
Q4. When does the GNSS measurement gap start if HARQ-ACK is disabled?
When the UE is not required to provide HARQ-ACK information for the associated transport block, the measurement gap starts at subframe n+6.
Q5. When does the GNSS measurement gap start if HARQ-ACK is enabled?
When HARQ-ACK information is required, the UE calculates the measurement gap starting point as k+2, where k is the first downlink subframe after the end of the associated PUSCH transmission.
Q6. What is the role of PDSCH in the GNSS Measurement Gap Procedure?
PDSCH carries the transport block containing the GNSS Measurement Command MAC CE from the eNB to the UE.
Q7. What is the role of PUSCH in this procedure?
When HARQ-ACK feedback is required, PUSCH carries the associated ACK/NACK response. Its transmission end determines the reference point k.
Q8. Does the UE monitor MPDCCH during the GNSS measurement gap?
No. The UE is not required to monitor MPDCCH during the GNSS measurement gap until it reacquires its GNSS position and performs contention-based Random Access.
Q9. What happens after GNSS position reacquisition?
After successfully reacquiring its GNSS position, the UE performs contention-based Random Access to support the resumption of the required network operations.
Q10. Which 3GPP specifications are relevant to the GNSS Measurement Gap Procedure?
The main specifications include 3GPP TS 36.213 for physical layer procedures, TS 36.321 for MAC procedures and TS 36.331 for RRC procedures.
Q11. What is the difference between n+6 and k+2?
n+6 is used when HARQ-ACK information is not required. k+2 is used when HARQ-ACK information is required, with k determined after the associated PUSCH transmission ends.
Q12. Which tools are useful for LTE-M NTN protocol testing?
QXDM, QCAT, Wireshark, protocol testing platforms and Python-based log analysis tools are useful for investigating signaling and troubleshooting issues.
Conclusion
The GNSS Measurement Gap Procedure is an important mechanism in LTE-M NTN that enables the UE to obtain updated GNSS positioning information without interfering with the required HARQ feedback procedure.
The LTE-M NTN eNB initiates the procedure by transmitting a GNSS Measurement Command MAC CE through the PDSCH.
The UE then determines the measurement gap starting time according to the HARQ feedback requirement.
When HARQ-ACK is not required, the measurement gap begins at n+6.
When HARQ-ACK is required, the UE first completes the associated PUSCH transmission and then starts the measurement gap at k+2.
During the measurement gap, the UE is not required to monitor MPDCCH until GNSS position reacquisition and contention-based Random Access are completed.
Understanding these procedures is essential for telecom engineers working on LTE-M NTN, IoT NTN, satellite communication, protocol testing and 3GPP standardization.
As NTN technology continues to evolve, knowledge of GNSS measurement, HARQ timing and network synchronization will become increasingly valuable for telecom professionals.
References and Further Reading
3GPP Technical Specifications
3GPP TS 36.213 – Physical Layer Procedures: https://www.etsi.org/deliver/etsi_ts/136200_136299/136213/
3GPP TS 36.321 – Medium Access Control (MAC) Protocol Specification: https://www.etsi.org/deliver/etsi_ts/136300_136399/136321/
3GPP TS 36.331 – Radio Resource Control (RRC) Protocol Specification: https://www.etsi.org/deliver/etsi_ts/136300_136399/136331/
3GPP Specifications Portal: https://www.3gpp.org/specifications-technologies/specifications
Explore More at Apeksha Telecom – The Telecom Gurukul
Website: https://www.telecomgurukul.com/
Build your expertise in 4G, 5G, 5G NTN, O-RAN, Protocol Testing and Log Analysis with industry-oriented telecom training.
Master Telecom Protocols. Build Real-World Skills. Advance Your Telecom Career.




Comments